EdenFantasys Newsletter Subscription Form
Take 20% off your order now - Get early access to deals and sales
Home>mall>Electronics
0Te renmen

RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A

4.875
$49.99 / $60.99
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$49.99 / $60.99
Shipping to: United States | Express delivery: 7-12 business days | Standard delivery: 15-25 business days

Checkout garanti an sekirite

Kado gratis
Kado gratis ak nenpòt acha
Règleman livrezon
Livrezon estanda gratis pou lòd plis pase $9.9
Règleman retou
Atik retounen yo pral aksepte nan 40 jou depi dat resepsyon machandiz yo. Atik pèsonalize pa ka retounen oswa echanje. Atik achte ak yon kat kado elektwonik ka echanje sèlman; rembousman yo pa aplikab.

Kado gratis

Byenveni nan Roymall, sit entènèt pwofesyonèl ou pou achte kado depatman magazen prim. Nou valè ak apresye sipò ou, epi nou vle eksprime rekonesans nou an nan ajoute yon touche eksitasyon siplemantè nan acha ou yo. Lè w ap fè makèt avèk nou, ou pa sèlman jwenn pwodwi ki gen bon jan kalite ki amelyore fòm ou, men ou pral resevwa tou yon kado gratis eksklizif ak chak lòd ou fè. Ou pare pou eksplore koleksyon nou an epi jwenn kado pafè ou yo? Parcou seleksyon nou an nan atik depatman magazen prim, fè lòd ou, epi tann eksitasyon kado gratis ou a ki rive ansanm ak acha ou.

Règleman livrezon

Nou pral travay di pou livre atik ba ou apre resevwa lòd ou yo epi asire yo rive an sekirite. Detay livrezon yo pral bay nan imèl konfimasyon ou.Nan pifò ka, lòd yo trete nan 2 jou.Nan sikonstans espesyal, li pral retade jan sa a: Lè ou fè yon lòd samdi, dimanch oswa jou ferye, li pral retade pou 2 jou..Nòmalman, li bezwen 5-7 jou ouvrab (lendi a vandredi) san yo pa afekte pa reta vòl oswa lòt faktè anviwònman..Paske sèvis livrezon nou an se mondyal, tan livrezon yo pral depann de kote ou ye kidonk li ka bezwen kèk tan epi tanpri rete pasyan si ou nan distri oswa peyi aleka.

1. Règleman Retounen & Echanj

Nou sèlman aksepte atik achte sou roymall.com. Si ou achte nan distribitè lokal nou yo oswa lòt revandè, ou pa ka retounen yo sou bò nou. Atik lavant final oswa kado gratis yo pa akseptab pou retounen. Pou kalifye pou yon retounen, atik ou a dwe itilize epi nan menm kondisyon ke ou te resevwa li. Li dwe tou nan anbalaj orijinal la.Apre resevwa enstriksyon retounen nan men nou, tanpri anbalaje atik retounen ou yo epi depoze pake ou a nan biwo lapòs lokal la oswa yon lòt kurye.
Nou pral trete atik retounen oswa echanj ou a nan 3-5 jou ouvrab apre nou resevwa li. Rembousman an pral trete ak kredite otomatikman nan metòd orijinal ou a nan peman.Pa gen retounen oswa echanj ka aksepte si pwodwi a te pwodui koutim, ki gen ladan gwosè koutim, koulè koutim, oswa enprime koutim.Bezwen plis èd, tanpri kontakte nou. service@roymall.com oswa Whatsapp: +8619359849471

2.Règleman Rembousman

Ou pral jwenn yon rembousman konplè oswa 100% kredi magazin apre nou resevwa pake retounen an epi verifye li. Rembousman an pral trete ak kredite otomatikman nan metòd orijinal ou a nan peman. Tanpri sonje ke frè livrezon ak nenpòt dwa oswa frè yo pa rembousab. Frè livrezon siplemantè yo pa rembousab yon fwa pake a te anbake. Ou responsab pou peye frè sa yo epi nou pa kapab egzante oswa rembouse yo, menm si lòd la retounen tounen vin jwenn nou.Yon fwa nou resevwa ak konfime atik retounen ou a, nou pral voye yon imèl ba ou pou fè ou konnen ke nou te resevwa atik retounen ou a. Nou pral tou fè ou konnen apwobasyon oswa rejè rembousman ou.Si ou gen nenpòt pwoblèm konsènan pwosesis rembousman an, tanpri kontakte nou. service@roymall.com oswa Whatsapp: +8619359849471
General Information:

The constant voltage and constant current programmable control power supply module put the collection of analog integration and digital control functions in one. Its adjustable output voltage range is 0-50.00V, step by 0.01V. Its adjustable output current range is 0-20.00A, step by 0.01A. This module has power-down stored function and can store 10 groups preset value. And it also has the function of extracting quickly two groups stored value. Compared with the traditional analog power supply, it is more convenient to quickly extract the voltage or current required. LCD display on the module has the function digital voltmeter and ammeter. You can view the preset voltage, input voltage, output voltage, the preset current, output current, output power, etc. on the output state remind area, you can see that output opens or not, the state of constant voltage and constant current, output is normal or not, the key is locked or not, and the current data groups that is being used. On the setting data interface, you can adjust overvoltage value, overcurrent value, over-power value, data set and LCD brightness. This module has many advantages, small size, advanced function, good visual effect, high operability, high-precision, being used independently, being inset into the device and been widely applied.

Type:


DPS5020 Communication + USB version

Very important:

1. Before buying this product, please download the upper computer software and test, if it fits your computer , you can buy
2. The upper computer only support For Win7 and above.
3. This is file for upper computer installation and software, you can download:
https://www.mediafire.com/folder/3iogirsx1s0vp/DPS_communication_upper_computer


Technical parameters:

Input voltage range: 6.00-60.00V Output voltage range: 0V-50.00V
Output current: 0-20.00A Output power range: 0-1000W
Product Weight: about 222g Display module size: 79*43*41(mm) (L*W*H)
Open size: 71mm*39mm Power module size: 93*71*41(mm) (L*W*H)
Length of connecting line: 200mm Fixed hole center distance: 86mm, 64mm
Output voltage resolution: 0.01V Output current resolution: 0.01A
Output Voltage accuracy: ± (0.5% + 1 digit) Output Current accuracy: ± (0.5% + 2 digits)
NOTE: 1.You must make sure that the input voltage is 1.1 times higher than output voltage. Under large current circumstances, pay attention to heat elimination.
2. Connection between display part and power part should be according to the corresponding words. Otherwise it will not work by wrong connection

Connection description:


IN+: Input positive IN-: Input negative:
OUT+: Output positive: OUT-: Output negative
Note: Input voltage range is DC 6-60V and 60v is the limit voltage; please leave a room to use. Or else it will be burnt. The input must be DC power supply, not AC 220V, or else it will be burnt too. Though this module has reverse connection protection and output short circuit protection, you can muse be in strict accordance with connection description to connect. If you connect the supply power with output, the module will be burnt.

Panel description:

1-Voltage setting/Page up to choose/Shortcut extract M1 data group
2-Data setting/ Extract value of the specified data group/Store value into the specified data group
3-Current setting/Page Down to choose/Shortcut extract M2 data group
4-1.44 inch color LCD screen
5-Coding potentiometer/Data adjustment/Lock all buttons
6-Open or close output

Display interface description:

7-The preset value of output voltage
8- The actual value of output voltage
9-The actual value of output current
10-The actual value of output power
11-The actual value of input voltage
12-The preset value of output current
13-Key lock or unlock prompt
14-Output normal or not prompt
15-Constant voltage and constant current status prompt
16-Data set prompt
17-Open or close output prompt

18-Preset output voltage
19-Preset output current
20-Preset over- voltage
21-Preset over-current
22-Preset over-power
23-Preset screen brightness
24-Preset data set
25-The actual value of output voltage and output current

Operating instructions:

When connect the power supply, the screen shows welcome window firstly and then comes into main interface. On the main interface, the output set voltage value and the output set current value is on the top of the screen. The big font value on the left are the current real output voltage, the current real output current and the current real output power. Input voltage is on the bottom of the screen. There are some running status icons on the right of the screen, key lock icon, abnormal output status icon, constant voltage and constant current icon, data set tip icon and opening or closing output icon.

Set the output voltage and output current on the main interface.
Press V/↑key shortly, you can enter into voltage setting status. Then press the coding potentiometer, and then enter to adjust the numerical value. Press coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. Turn by clockwise rotation to increase the numerical value; Turn by counterclockwise to decrease the numerical value. If you want to exit adjusting the numerical value, press shortly V/↑. In the same time the preset value will be stored. Or you can do nothing in one minute, the status will be automatically existed and the preset will be stored too. You can press A/↓to set the output current by the same way.

Set the data on the data setting interface
On the main interface, you can press SET key shortly to enter into data setting interface. On the data setting interface, press shortly V/↑or A/↓ to page up or page down to U-SET or I-SET, and then set the output voltage and output current by same way used in the main interface .
Set the protection value.
Page up or page down to S-OVP, S-OCP or S-OPP place to set over-voltage value, over-current value and over-power value correspondingly; when the value is up to the setting value, output will be closed. And then press shortly the coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. If you want to exit adjusting the numerical value, press shortly SET key.

Adjust the brightness of screen.
Page up or page down to B-LED, and then press shortly the coding potentiometer to enter into the status of adjusting the brightness of screen. Turn coding potentiometer to adjust the numerical value you need. If you want to exit adjusting the numerical value, press shortly SET key. There are six brightness levels of LCD screen, 0-5 level. Rank 0 is the darkest; rank 5 is the brightest. You can choose what you like.

Data setting and store the specified data group.
Page up or page down to M-PRE, and then press shortly the coding potentiometer to enter into the status of choosing the data groups. Turn coding potentiometer to choose the data group you need to view. Then the data group you need will be displayed. And then press the coding potentiometer to enter into status of changing output state. Turn coding potentiometer to choose ON or OFF. When choose ON, the data group is extracted and the output status remain the same. When choose OFF, the data group is extracted and the output is closed. If you want to exit choosing data set, press shortly SET key. Then press shortly V/↑or A/↓ to page up or page down to other place to adjust the data you need. After data setting done, keep pressing SET key more than 2s, all the data you set are automatically stored into the specified data group. In the same time, you can see the group number on the right of screen. At last you can press shortly SET key back to the main interface.

Set default boot open or close output
Page up or page down to S-INI, and then press shortly the coding potentiometer to enter into the setting status. Set ON, default boot open; set off, default boot close.

Function description:

Open or close the output.
You can press ON/OFF key to open or close the output on any interface.

Lock the button to avoid wrong operation.
On the any interface, you can keep pressing coding potentiometer more than 2s, all buttons are locked. You can see the key lock icon on the right of screen. If you want to unlock all buttons, keep pressing coding potentiometer more than 2s, all buttons are unlocked. The key unlock icon will be displayed on the right of screen.

M0-M9 ten groups data group.
M0 group is the boot default data group. When you extract the data group you need, this data group will cover M0 data group and be automatically stored on M0 data group.

Extract Shortcut storage data group M1 or M2.
On the main interface, keep pressing V/↑or A/↓ more than 2s, you can extract Shortcut storage data group M1 or M2 quickly. In the same time, the corresponding data group number will displayed on the right of the screen.

Extract the specified data group.
On the main interface, keep pressing SET key more than 2s, the sequence number of data group will be displayed on the right of the screen, you can turn coding potentiometer to choose data group you need. And then press shortly SET key, you can extract the specified data group you need.

Package included:

1 x DPS5020 USB LCD Voltmeter



Electronics Ranking
RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A

RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A

RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A

RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A

RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A

RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A
RIDEN® DPS5020 USB Communication Version Constant Voltage Current Step Down Module Power Supply Buck Voltage Converter LCD Voltmeter 50V 20A

Customer Reviews

5.00 out of 5
See all 6 reviews
Write a Review
  • All Reviews (6)
  • Image ( 2 )
  • Video (0)
  • All Star
    • All Star(6)
    • 5 Star (2)
    • 4 Star (0)
    • 3 Star (0)
    • 2 Star (0)
    • 1 Star (0)
Sort by:
Top Review
  • Top Review
  • Most Helpful
  • Most Recent
Reviews only from your country (United States)
|
Show Original

A part of the review has been auto-translated.

  • 14/05/2019

    Rất đẹp tôi sẽ làm 1 clip review trên YouTube hãy chờ nhé. Hoàn thiện chất lượng cao. Vận chuyển rất nhanh chỉ mất 11 ngày.

    Comments (0)
    Show Original
  • 25/05/2019

    it nice.!!!!!!!!!!!!!!!!!!!!!!!!!!!!
    cool
    I happy++++++++++++++++++++++++++++++++++++++++++++++++++++

    Comments (0)
    Show Original
Show:
    12...30

    Total 0 pages

    Go to page

    Go
    Customer Q&As
    Can't find your answer? Ask a new questionorCustomer Service

    Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.

    showing 1-1 of 1 |
    Show Original

    A part of the QA has been auto-translated.

    Kabwa mwen Kabwa (0)
    Favori mwen Favori mwen (0)